We also manufacture ferrules - including wire ferrules and electrical ferrules - as well as tooling products designed to help you properly crimp our products. I have found lots online saying there arent different kinds and that any should bolt right up but obviously not.TE terminals and splices are engineered for reliable connections. Our portfolio includes a variety of terminals and splices, including ring terminals, spade terminals, PCB terminals, receptacles, pin terminals, insulated quick disconnects, wire terminals, crimp terminals, solder terminals, and solder splices. So question is are there two types of pushmatic breakers OR why are these different? (also note the plastic 'wings' on the side and the 'feet' on the bottom) Most importantly the bolt holes do not line up the same where it would mount into the panel. I bought a 60A pushmatic breaker that appeared to be the same but upon further inspection there are a few differences. The bottom line how the TYCO got approve is the bottom line is the manufacter will find a way to get around the code to speed up the whole thing and I never personally like it too much at all. I have dealt few of them allready before with manufacted homes QAAV.GuideInfo - Nonmetallic-sheathed Cable Interconnectors Joe.,Īs we are aware with the Art 545,550,551 they are only used in mobile home and RV useage but for perament resdnetail useage that get sticky that why my personal option I advoid them much as I can those item are very and I mean very last resort to use them that the main reason why I rather use the proper junction boxes and go from there. I have never seen them before, but when checking the manufactuer's website copyrighted 2009, it states the following: QAAV.GuideInfo - Nonmetallic-sheathed Cable Interconnectors Here is some additional information from the U.L. IMO they violate the spirit of good workmanlike practice in that all splices and junctions should be accessible although they appear to be code compliant in some situations or at least they were in the 2002 NEC. Article 334-40B allows these devices to be used without boxes in exposed cable wiring and rewiring in existing buildings where the cables is concealed or fished. When I checked NEC articles 545, 550 and 551 (in the 2002 NEC) I found that these articles apply to Manufactured Buildings, Mobile Homes and Mobile Home Parks and Recreational Vehicles and Recreational Vehicle Parks. Has anyone checked these articles in the 2008 NEC? Meets requirements of NEC 2002 articles 545, 550, 551 and 334-40B (Tap and 3-Wire Interconnection)ĪMP NETCONNECT Non-Metallic (NM) Sheathed Cable Interconnections Where connections to conductors are by binding-screw terminals, there shall be available as many terminals as conductors. Openings in such devices shall form a close fit around the outer covering of the cable, and the device shall fully enclose the part of the cable from which any part of the covering has been removed. Switch, outlet, and tap devices of insulating material shall be permitted to be used without boxes in exposed cable wiring and for rewiring in existing buildings where the cable is concealed and fished. NEC compliant - article 334-40b, 2005 & 2008 NECģ34.40(B) Devices of Insulating Material. NEC approved Article 334-40b.įor Use On 12 or 14 AWG (300 Volt) 2 wire NM cable with ground Splice and Tap Kits also eliminate wire nuts for installation and replace the conventional method for adding a splice or tap for non-metallic cable without the need for exposed and unsightly junction boxes. They are designed and approved for use in rework within existing structures. Tyco Electronic's Non-metallic splice and tap kits provide a fast and reliable method for splicing or tapping 2 wire w/ ground and splicing 3 wire w/ground non-metallic cables up to 300 volts. Here's the product info I found on the HD web site: None of the descriptions I read indicate any restrictions on their use beyond what i pasted below. A quick Google shows that they are available from lots of suppliers. I don't remember seeing these splices at HD before. It appears that they may have been approved for use beyond manufactured homes. The attached file is nearly 10 years old.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |